Why it matters at all
A normal household circuit is built for power flowing one way: from the breaker panel, along the wire, out to whatever is plugged in. The breaker protects that wire by measuring the current coming from the panel. A plug-in kit feeds power in at an outlet partway along the circuit, downstream of the breaker. If a space heater and a microwave are running on the same circuit while the kit is producing, part of the wire can end up carrying the grid current and the solar current together, and the breaker only ever sees the grid part. UL makes this exact point in its safety paper on plug-in PV: the combined current can go past what the wire is rated for without the breaker tripping.
Rough numbers at 120 volts:
- 400 W is about 3.3 A
- 800 W is about 6.7 A
- 1,200 W is about 10 A
What the state laws say
There is no single national rule, and the states differ more than people expect.
- Maine splits it in two. Up to 420 W you can install a kit yourself. Above 420 W and up to 1,200 W the law requires a licensed electrician and a dedicated circuit with a single outlet.
- Maryland and Colorado both draw a line at 391 W. Devices at or below that are exempt from the listing requirement, and anything bigger has to be listed by UL or an equivalent lab. Some summaries say Colorado also requires an electrician and a dedicated circuit above that line. The summaries disagree with each other, so read the bill text before relying on either version.
- Most of the other laws we have read, including the 1,200 W ones, lean on certification rather than wiring rules: the kit has to be listed, plug into a standard outlet and shut itself off when the grid goes down.
How to decide for your own home
- Find out what else is on the circuit. Switch off the breaker you think it is on and go round with a lamp or a phone charger to see which outlets went dead.
- If that circuit also feeds heavy loads like a space heater, kettle, toaster, window AC or hair dryer, use a different outlet or plan for a dedicated circuit.
- If the circuit only serves a bedroom or a balcony outlet with light loads, a smaller kit is low risk, and a 400 to 800 W kit leaves far more margin than a 1,200 W one.
- If you are in Maine and going above 420 W, the decision is already made: electrician and dedicated circuit.
Old wiring, outlets that already feel warm, and extension cords. Plug the kit straight into a wall outlet, and if the manual says no extension cords, take that literally. If you have any doubt about the wiring, paying an electrician to check one circuit costs very little next to the price of the kit.
Last updated: October 12, 2026