New Hampshire plug-in solar law (SB 540) explained

State laws, utility rules and certified kits.
Thurgood
Site Admin
Posts: 72
Joined: Thu Oct 08, 2026 6:20 pm

New Hampshire plug-in solar law (SB 540) explained

Post by Thurgood »

New Hampshire's plug-in solar law is SB 540, signed by Governor Kelly Ayotte on July 2, 2026 as Chapter 262. Most of it takes effect on January 1, 2027, but there is a catch: the building code part only starts once a national standard exists for safely connecting these systems, and some local officials are urging caution.

What the law allows
  • One plug-in device per metered customer
  • Up to 1,200 W of AC output per meter
  • The system connects through an outlet or another non-permanent connection
  • The rules apply to every metered customer, so renters with their own meter are included
Safety standards
Systems must be certified by a nationally recognized testing laboratory. The law does not name UL 3700 specifically, and it says state rules may not go beyond the applicable ANSI, IEEE or UL test standards. The section that brings plug-in systems into the state building code only takes effect once the Commissioner of Energy certifies that a nationally recognized standard exists for safely connecting them to a building's wiring. In September 2026 Dover's energy commission and the city's electrical inspector urged residents to be cautious until that is settled.

Utilities
Utilities cannot require an interconnection agreement, cannot add their own fees, other than normal usage charges, or extra equipment, and cannot make you seek approval. They may set up a way for customers to record the size of the system they installed. The law also shields utilities from liability if a plug-in device causes damage or injury, which means the responsibility sits with the owner.

Net metering
Plug-in devices are outside net metering. Do not expect credit for power you send back to the grid.

Insurance warning built into the law
The Department of Energy has to tell the public that connecting a system that is not listed, or connecting one against the building code or the manufacturer's instructions, may affect your homeowners or renters insurance. Call your insurer before you buy.

Older homes
Reporting on the law has highlighted the overload and fire risk in older wiring, which is a large part of the caution above. A plug-in kit feeds power into a circuit that can also be drawing power from the panel, and the breaker cannot see both. The safe fixes are a dedicated circuit installed by an electrician, a power control system, or wiring rated for the combined load.

Renters
The law covers renters, but it does not spell out how lease terms are handled. Tell your landlord before anything goes on the balcony.

Source: SB 540 bill status (New Hampshire General Court)

Last updated: October 19, 2026. This is a summary of SB 540, not legal advice.