What a GFCI does
A GFCI compares the current going out on the hot wire with the current coming back on the neutral. If some of it is leaking somewhere else, for example through a person, it trips in a fraction of a second. That is why outdoor outlets have them, and why you should never take one out.
Why a plug-in kit is an odd fit
GFCI outlets and breakers are built and tested for power flowing one way, from the panel out to whatever is plugged in. A plug-in kit pushes power the other way. UL makes this point in its safety paper on plug-in PV: the current GFCI standards assume one-way current, and power flowing back through the device could leave the circuit less protected than it looks. UL's suggested fix is a GFCI designed for two-way flow, which most homes do not have.
Electricians who have looked at the physics disagree on how much this matters in practice. Some argue the GFCI still sees a fault whichever direction the current comes from. Others think part of a fault could be missed when there are two sources on one circuit. Nobody claims an ordinary GFCI is listed for this use.
Will it trip?
In normal running a kit puts out balanced current, so it should not trip a healthy GFCI. Nuisance trips do get reported, usually blamed on electrical noise from the inverter, on moisture, or on an old GFCI. If the GFCI does trip, the kit loses its connection to the grid and switches itself off within a second or two, as every certified microinverter has to. So a trip stops the kit as well as the circuit.
What UL 3700 changes
UL 3700 is the first US standard written for plug-in solar as a complete system. It was published in December 2025 as an outline of investigation, which means it can still change, and it is meant to deal with exactly these questions: overloading the circuit, live plug pins and ground fault protection. Some summaries say certified kits will use their own plug and outlet rather than a standard household one, and UL's paper lists unique plugs and dedicated outlets among the possible fixes. Until certified kits are actually on sale, follow whatever the manual of your kit says about GFCIs and circuits.
What to do in the meantime
- Never replace a GFCI outlet with a plain one to stop it tripping, and never run an extension cord from an indoor outlet to get around it. The GFCI is what protects you outdoors.
- Press the TEST button once a month, and at least once with the kit running. It should trip straight away both times. If it does not trip with the kit running, unplug the kit and get an electrician to look at it.
- If it trips repeatedly with the kit plugged in, unplug the kit for a while and see whether the trips stop. If they do, talk to the kit maker and an electrician rather than living with it.
- Buy a certified kit, and once UL 3700 kits arrive, prefer one of those.
- If you are paying an electrician anyway, ask about a dedicated circuit for the kit. It removes the overload worry, and the electrician can set up the ground fault protection properly for that circuit.
Last updated: October 2026